PAGE 44 — LD6 RIDE-ON POWER TROWEL • OPERATION MANUAL — REV. #0 (02/10/20)
Trowel Troubleshooting (Continued)
Symptom Possible Problem Solution
Lights (optional) not working.
Wiring?
Check all electrical connections, including the master
ON/OFF switch and check to see if wiring is in good
condition with no shorts. Replace as necessary.
Lights?
Check to see if light bulbs are still good. Replace if
broken.
Retardant spray (optional) not working.
Retardant? Check retardant level in tank. Fill tank as required.
Wiring?
Check all electrical connections, including the master
ON/OFF switch connections. Replace components and
wiring as necessary.
Bad switch?
Check the continuity of the master ON/OFF switch.
Replace if broken.
Bad spray pump?
If pump has a voltage present when the switch is turned
on but does not operate, and electrical connections to
the pump are good, replace the pump.
Bad fuse? Check fuse. Replace fuse if defective.
Steering is unresponsive.
Worn components?
Check for wear of steering bearings and linkage
components. Replace if necessary.
Pivots? Check to ensure free movement of hydraulic drive motors.
Hydraulic pressure?
Check to ensure that hydraulic steering pressure is
adequate.
Pitch system not working.
Wiring? Check and repair wiring and connectors as necessary.
Actuators? Check pitch system fuses. Replace if necessary.
TROUBLESHOOTING