3.9 Errormessages
An overwiev of possible errors which prevent normal operation.
3.9.1 MK30D-MK60D
Errormessages Illustration Cause Remedy
Yellow light on centre
LED w ith emptying
symbol and FULL on
display.Seeemptying
guide below, or check
pump outlet
Water container is full
or fault on water pump
(accessory)
See emptying guide
below, or check pump
outlet
Red light on right
warning LED HIGH
TEMP on display
Pressure or temperature
in high pressure element
too high
Check lter and
dehumidier for dirt
in airways
Red light on right
warning LED
AMBIENT TE M P
on display
Room temperature out
of normal range
Place the dehumidier in
the specied temperature
range, between 3°-32ºC
SENSOR FAIL
1: EVAP FAIL
Evaporator
thermometer defective
Requires an authorised
service technician
2: COND FAIL
Condenser
thermometer defective
Requires an authorised
service technician
Red light on right
warning LED
SENSOR FAIL on
display. One of the
inter nal sensors is
defective. Use the +/-
keys to toggle between 3
possible errors
3: ROOM FAIL
The internal room
thermometer is
defective
Requires an authorised
service technician
Red light on right
warning LED LP
STOPon display
Leak in cooling circuit Requires an authorised
service techn ician
15 Operation 190TEN-1071-C1304