© Munters AB, 2016 29
Parameter Name
Default Value
Increment Value
Min Value
Max Value
Time From
08:00 1 00:00 23:59
Time To
17:00 1 00:00 23:59
Table 6: Soaker Parameters Summary
Parameter Name
Default Value
Increment Value
Min Value
Max Value
Temp Diff On
2.0
°
F
0.1
0
°
F +60
°
F
Temp Diff Off
1.0
°
F
0.1
0
°
F +60
°
F
Soak to Hum (%)
85 1 0 100
On Time (sec)
120 1 0 999
Off Time (sec)
480 1 0 999
Time From
08:00 1 00:00 23:59
Time To
17:00 1 00:00 23:59
Table 7: Alarm Parameter Summary
Parameter Name
Default Value
Increment Value
Min Value
Max Value
High Temp Diff
10.0
°
F 0.1
°
F 1
°
F 99
°
F
Low Temp Diff
-10.0
°
F -0.1
°
F -1
°
F -99
°
F
Delay (sec)
60 1 10 999
Reminder
60 1 0 999
Table 8: Calibration Parameter Summary
Parameter Name
Default Value
Increment Value
Min Value
Max Value
Thermometer 1/2/3
± 0.1 -9.0 º +9.0º
Humidity (%)
0 1 -25 25
Water Counter
1.0 0.1 0.1 999.0
Curtain Open/Close (seconds)
60 1 0 999
Fan-1/2/3 Min Volt
0.0 0.1 0.0 10.0
Fan-1/2/3 Max Volt
0.0 0.1 0.0 10.0
Table 9: System Menu Summary
Parameter Name
Default Value
Increment Value
Possible Value
Control Method
Temp N/A Temp/THI
Temp-3
Out N/A Out/In
Wind Speed
32 1 0 to 80