© Munters AB, 2016 8
o
Munters Drive 2: Foggers
o
Munters Drive 3: Foggers
Relay controlled fans
: There are three relay controlled fans that provide additional
ventilation. These fans turn on when the Munters Drive fans turn on.
3.2.3 Curtains
The controllers open and close curtains according to temperature readings. In the presence of high
wind speeds, the curtains can be set to a minimum position.
3.3 User interface
LED indicator:
ON/OFF state of each LED indicates whether the relay is operating or idle.
Prog
key:
Navigate to the parameters in main menus and edit parameters (press once to
enter edit mode, press again to exit edit mode).
Down / Up arrow keys:
Increase/decrease parameter values, navigate Hot Keys (see
Hot Keys
section) and menus.
Select key:
o
Navigates in and out of main screen and menus (press once to enter main menus,
press again to exit).
o
Erase changes made to parameters. If you change a parameter incorrectly, click
Select
and the parameter reverts to the previous definition.
Summary: To get to menu items:
1. Press
Select
.
2. Press
Up/Down
to reach the required menu.
3. Press
Prog
to enter the menu.
4. Press
Up/Down
to reach the menu item.
5. Press
Prog
to edit the item.
6. Edit as required.
7. Press
Prog
.
8. Press
Select
.
For example, to go to Curtain A configuration, from the main screen, press the following keys:
Select > System
>
Curtain A.
, until the required parameter appears.
NOTE After changing any parameter, you must go to the main screen to save the change.
3.4 Hot keys
The
SMART-8C/3MD
can display key data on the screen (no need to enter the menus). To access
this data, on the Main screen, press the ▼▲ keys.
Data displayed
:
Current average temperature, target temperature, and time
o
In THI Mode: Current THI and Target THI
Individual temperature sensors readings
o
In THI Mode: Individual humidity sensor readings and average temperature
Current humidity
1 to 3 Munters Drive fan operation percentage