© Munters AB, 2016 9
•
Current position, next step time, and state messages
o
Locked: Controller has set the curtains to 0 or 100%.
o
Working: Curtains are changing position
o
Min Pos: Curtains are at the designated minimum position
o
Idle: Curtains are in the Happy Zone and do not move
o
Cal Req!: Curtains require calibration (usually happens after a cold start)
o
Calib: Curtains are calibrating
•
Fogger cycle state timing
•
Soaker cycle state timing
•
Daily water consumption
3.5 Menu structure
Table 1: Menu Structure
Temperature
set point
Curtain
settings
High
temperature
differential
Temperature
sensor 1 - 3
Temperature
sensor 1 – 3
Control method
Fans 1 - 3 Low
temperature
differential
Humidity
sensor
Humidity sensor Temperature 3
definition
Fogging &
soaking
settings
Delay
(seconds)
Analog Output
1 - 3
Water counter High wind speed
Reminder Relays 1 - 8 Curtain open Calibration steps
Digital inputs
1 - 2
Curtain close Measurement unit
Software
version
Fan 1 – 3
minimum/maximum
voltage
History
LCD version Current time
Communication
version
Unit Number
Hardware
version
Baud rate
System reset
LCD test
3.6 General features
•
If a screen other than the main screen is displayed for five consecutive minutes, the system
returns to the main screen display automatically (in menus only, not including Hot Keys).