4.4.3 Configuring the curtains
The following section details how to configure the curtains.
Connect curtains as shown in Figure 8.
1. Press
Select
.
2. Scroll to Settings and press
Prog
.
3. Scroll to Curtains and press
Prog
.
4. Set the following parameters:
o
Temp Diff Below
: The differential from the target temperature from which the
curtain closes entirely.
o
Temp Diff Above
: The differential from the target temperature from which the
curtain opens entirely (100%).
o
Stage Delay
: Define the delay time (from the previous current movement) before
the next current opening or closing.
o
Step Size
: Define the increment (in percentage) between each level.
o
Minimum Position
: Minimal opening percentage
o
Time From
: Beginning of the time period in which the curtains can operate
o
Time To
: End of the time period in which the curtains can operate
NOTE Setting the time from 00:00 to 00:00 enables 24 hour operation. Setting
any
other
identical times (for example 13:15 to 13:15) disables the curtains.
5. After setting each parameter, press
Prog
.
6. Press
Select
.
7. Scroll to System and press
Prog
.
8. Scroll to High Wind Speed and press
Prog
.
9. Define the wind speed above which all devices turn off and curtain goes to minimum
position.
10. Press
Prog
.