3-41
Memory switch 06x : Remote reception
Memory switch 065 :
bit
Initial
Setting
Adjust Usage / Comments
7 0
Adjustment of CI detect
time
Sets the time added to or reduced from the CI detect time.
Switch 76543 Time
11111 150 msec
11101 140 msec
: :
01001 40 msec
00111 30 msec
00101 20 msec
00011 10 msec
00000 0 msec Initial setting
00010 -10 msec
00100 -20 msec
00110 -30 msec
01000 -40 msec
: :
11100 -140 msec
11110 -150 msec
6 0
5 0
4 0
3 0
2 0
Factory use only —
1 0
Factory use only —
0 0 Beep if fax handset is
hanged up
0 : Yes
1 : No
Determines if your machine beeps when having left the fax’s
handset hanging up after communication.
Memory switch 066 ~069 : Factory use only