3-44
Memory switch 07x : Operation
Memory switch 076 :
bit
Initial
Setting
Adjust Usage / Comments
7 0 Timing to turn off the S-
Relay at fax reception.
Adjust this setting when a private exchanger disconnects the
line when S-Relay is turned off.
Bit 7654 time
1111 1500 milliseconds
1110 1400 milliseconds
: :
1010 1000 milliseconds
1001 900 milliseconds
0100 800 milliseconds
: :
0100 500 milliseconds
0100 400 milliseconds
0011 300 milliseconds
0010 200 milliseconds
0001 100 milliseconds
0000 10 milliseconds (default)
6 0
5 0
4 0
3 1 Display when there is no
TTI
0 : No
1 : Yes
2 0 Factory use only
1 1 Factory use only
0 0 Factory use only
Memory switch 077 ~ 079 : Factory use only
Memory switch 08x : Not used