29
Multimeter features
The uncertainty of all ranges is expressed as: ± (a% reading + word count). The correction period is one year.
The environmental conditions with guaranteed uncertainty are: 23°C±5°C, <75%RH.
Function
Range
Resolution
Uncertainty
DC voltage
400mV
0.1mV
(1.5%rdg + 10dgt)/1000V
4V/40V/400V/1000V
1mV/10mV/100mV/1V
AC voltage
400mVManual range
0.1mV
50Hz ~1kHz
(2.0%rdg + 10dgt)(More
than 1kHz is not evaluated)
4V/40V/400V
1mV/10mV/100mV
50Hz~400Hz
(1.0%rdg + 10dgt)
400Hz~20kHz
(5.0%rdg + 10dgt)
750V
1V
50Hz ~1kHz
(1.5%rdg + 10dgt)(More
than 1kHz is not evaluated)
DC current
40mA /400mA
10µA /100µA
(1.2%rdg + 10dgt)
4A/10A
1mA/10mA
AC current
40mA /400mA
10µA /100µA
50Hz~5kHz
(1.5%rdg + 10dgt)(More
than 5kHz is not evaluated)
4A/10A
1mA/10mA
Resistance
400/4K/40K/400K/4M
40M
0.1Ω/1/10/100/1K
10k
(1.0%rdg + 5dgt)
(3.0%rdg + 5dgt) / 40M