EasyManuals Logo
Home>mycom>Air Compressor>2016LMC

mycom 2016LMC User Manual

Default Icon
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
2200LZJE-HO-C6-N_2013.12.
Chapter 2 Configuration and Specifications of Compressor
Compound 2-stage Screw Compressor 2016**C 2.1 Features of the Compound 2-stage Screw Compressor 2016**C
2-1
Chapter 2 Configuration and Specifications of
Compressor
2.1 Features of the Compound 2-stage Screw
Compressor 2016**C
The 2-stage compression system, which has hitherto required two units of standard-type screw
compressor for its embodiment, can now be realized by a single unit of compound 2-stage screw
compressor.
Generally, screw compressors use oil injection to keep discharge temperature at a low level during
operation without loss of volumetric efficiency even at high compression ratios. It can, therefore, be
operated with a single-stage compression system even at evaporative temperatures near -40°C.
However, for normal use at low temperatures, a 2-stage compression system is applied in order to
improve KW/RT (ratio of power consumption versus cooling ability). If the 2-stage compression system
is configured with standard-type screw compressors, at least two screw compressor units need to be
installed, one on the high-stage and the other on the low-stage, which inevitably requires double
installation of the entire system including machinery, motors, utilities, etc.
This 2-stage screw compressor is produced to solve this problem. It is a single unit that has two
single-stage compressor units combined into one.
The 2016**C model has a capacity control mechanism for startup load reduction on the high-stage, and
a capacity control mechanism for coping with load change on the low-stage.
There are various combinations of machine control methods/capacity control methods. However, as
they are not directly related to the inspection of the compressor, they are omitted here.
2.2 Model Designation of the Compressor
This manual describes 2016**C-*B*-51 and 2016**C-*B*-61 models.
The meaning of the type designation, which is engraved on the MODEL column of the compressor
nameplate, is as follows.
*2016**C-*B*-51/61
5: Power frequency (6: 60Hz)
1: Indicates that it is a motor directly connected type.
* Unless specifically specified, machines manufactured in
September, 2010 or after do not have this indication engraved
on their nameplate.
Vi (volume ratio) specified for the high-stage discharge port,
standard value of which is L or M
Means a booster (low-stage machine)
Vi (volume ratio) specified for the low-stage discharge port, standard
value of which is L or M
Stands for Compound (compound 2-stage machine)
Specifications of high-stage rotor length, which is L, M or S
Specifications of low-stage rotor length, which is L, M or S
High-stage rotor diameter of 160
Low-stage rotor diameter of 200
Indicates working fluid
(Example: N = Ammonia, F= Freon, P = Propane, HE = Helium)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the mycom 2016LMC and is the answer not in the manual?

mycom 2016LMC Specifications

General IconGeneral
Brandmycom
Model2016LMC
CategoryAir Compressor
LanguageEnglish

Related product manuals