WI850D GEM-P800 Installation Instructions
12
Remote Activation
Using NAPCO's Quickloader Software
(Version 3.26 or higher), follow the instruc-
tions below:
From the Status Screen
Press F6
Select Miscellaneous Control
Select Enable Signal Strength Logging
Uploading Signal Strength Information
from the Log
After approximately (2) two hours, re-
establish a connection with the panel. Sig-
nal strength log information ranges from 1
to 10. The logging of signal strength should
appear similar to the sample LOG below:
Zone Features
[00] Exit/Entry Zones
Delay allows exit and entry through an Exit/
Entry Zone after the system is armed with-
out setting off an immediate alarm. Exit De-
lay allows the user to leave the premises
after arming. Entry Delay allows the user
time to enter and disarm. The entry delay
may be canceled by pressing
F..
[01] Home/Away with Delay Zones
Zones that automatically bypass at the expi-
ration of the exit delay if the EXIT/ENTRY
zone(s) are not violated. Zones of this type
have a three (3) minute power-up delay,
and do not display or cause an alarm if
faulted when the system powers up. Press-
ing the
C key cancels the 3 minute timer.
If Exit/Entry zone(s) are violated during the
exit delay, zones programmed as Home/
Away with Delay Zone(s) will have a fixed
20-second entry delay, if violated before
the
Exit/Entry zone.
To eliminate this fixed 20-second entry de-
lay, also program zones as Exit/Entry Fol-
lower Zones [02].
To return protection to zones of this type,
press
BC from the keypad or M or
N from a Keyfob. Program the Keyfob
AUX 1 or AUX 2 button for Full Set [81-7].
[02]Exit/Entry Follower Zones
Entry Delay allows the user time to enter and
disarm. Allows exit after the panel is armed
without setting off an immediate alarm and
allows entry only if an Exit/Entry Zone [00]
has been violated first. Zones of this type
have a three (3) minute power-up delay, and
do not display or cause an alarm if faulted
when the system powers up. Pressing the
C key cancels the 3 minute timer.
Group Bypassing - Zones programmed as
Exit/Entry Follower Zones will be Group by-
passed if the
E key is pressed while dis-
armed or within the Exit Delay.
Auto Interior Bypassing - Also program
zones as Home/Away with Delay Zone(s)
[01] to automatically bypass at the expiration
of the exit delay if the EXIT/ENTRY Zone(s)
are not violated during the exit delay.
[03]Auto-Bypass Reentry Zones
Zones programmed as this zone type are
permitted to be faulted at the time of arming.
Once the zone is restored, while the control
panel is still armed, the zone will automati-
06/01/09 17:44 QL: Full Program Uploaded
06/01/09 17:42 QL: Technical Connection
(callback) Technician 2
06/01/09 15:23 Transmitter Status: GEM_SMK 1
(7A0DB5): SS=7
06/01/09 15:13 Transmitter Status: GEM_SMK 2
(768447): SS=8
06/01/09 15:13 Transmitter Status: Zone 2,
SS=6
06/01/09 14:27 Trouble: RF Link, GEM_RECV 1
06/01/09 14:25 Panic: Keypad
06/01/09 14:25 Panic: Keyfob 1(933780) SS=8
06/01/09 14:25 Dealer Program Mode Entered
06/01/09 14:24 Instant: Keyfob 1(933780)
SS=8
06/01/09 14:24 QL: Connection Terminated (10
MIN T/O)
06/01/09 13:13 QL: Full Program Downloaded
05/07/09 12:06 Open: User 2
05/07/09 12:06 Close: EasyArm
05/07/09 11:55 Trouble Restore: Low Battery,
GEM_SMK 2(768447) SS=8
05/07/09 10:21 Transmitter Status: GEM_SMK
(7A0DB5): SS=6
If A0 is Entered during Exit Time, Home/Away with
Delay Zones will be automatically bypassed, even if the
Exit/Entry Zone is violated. Easy Exit/Easy Arm [22-2] must
be enabled.
NOTE: