Leak Tesng Instrucons
WARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a part
of the gas system is replaced.
WARNING! Never use an open ame to check for gas leaks. Be certain no sparks or open ames are in
the area while you check for leaks. Sparks or open ames will result in a re or explosion, damage to prop
erty,
serious bodily injury, or death.
Leak tesng: This must be done before inial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak Tesng
Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one recommended
by the Napoleon Customer Care department and have the grill inspected by a cered gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill inspected
by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.

Other manuals for Napoleon LD485RSIB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Napoleon LD485RSIB and is the answer not in the manual?

Napoleon LD485RSIB Specifications

General IconGeneral
BrandNapoleon
ModelLD485RSIB
CategoryGrill
LanguageEnglish

Related product manuals