18.3 BLOWER AIRFLOW
H3.77
DISCONNECT THE ELECTRICAL SUPPLY TO THE FURNACE BEFORE ATTEMPTING TO
CHANGE THE BLOWER SPEED. FAILURE TO DO SO COULD RESULT IN ELECTRICAL
SHOCK RESULTING IN PERSONAL INJURY OR LOSS OF LIFE.
WARNING
!
!
TABLE 7A
NOTE: Heat speed and Cooling speed not to be connected on same motor tap. Low and High Cooling
speed not to be connected on same motor tap.
WSX040T2AA
ESP (in. WC) Low Heat (1) High Heat (2) 1.5T Cool (3) 2.0T Cool (4) 2.5T Cool (5)
1*
0.9*
0.8*
0.7*
0.6*
0.5 165 475 365 695 910
0.4 235 515 410 730 940
0.3 285 560 460 755 965
0.2 375 600 510 785 990
0.1 515 635 550 810 1015
* Values for ESP above 0.5” W.C. are provided for reference only and above the certifi cation design parameters of this ap-
pliance. Always refer to and follow the rating plate for allowable installation parameters.
WSX060T3AA
ESP (in. WC) Low Heat (1) High Heat (2) 2.0T Cool (3) 2.5T Cool (4) 3.0T Cool (5)
1* 295 630 455 830 1015
0.9* 335 665 495 865 1085
0.8* 385 715 535 895 1110
0.7* 430 750 580 940 1140
0.6* 470 795 635 985 1175
0.5 530 840 680 1010 1210
0.4 585 880 720 1045 1235
0.3 640 920 770 1085 1265
0.2 695 970 820 1120 1295
0.1 745 1000 860 1165 1325
WSX080T3AA
ESP (in. WC) Low Heat (1) High Heat (2) 2.0T Cool (3) 2.5T Cool (4) 3.0T Cool (5)
1* 315 775 435 675 1180
0.9* 365 815 485 720 1205
0.8* 415 895 525 760 1240
0.7* 470 940 575 840 1270
0.6* 530 990 630 885 1300
0.5 585 1030 710 930 1330
0.4 660 1070 760 975 1360
0.3 705 1110 815 1015 1390
0.2 755 1145 865 1070 1420
0.1 815 1185 915 1105 1440