ELT-400 7 Remote control
7-17
Instrument status query
CALC:BAT<SP><param>[CR]<LF>
CALC:BAT?[CR]<LF>
Response:
<param><CR><LF>
Meaning:
Activates / deactivates battery status information.
The battery status is appended to the response values for a field
measurement.
ª Remote control command MEAS, see page 7-14
param Explanation
ON Battery status response with every measured value transfer.
OFF No battery status response.
Table 7-12 Battery status response settings