EasyManuals Logo

National Instruments SCXI-1000 Getting Started

National Instruments SCXI-1000
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
Chapter 4 Connecting and Using Accessories and Transducers
Getting Started with SCXI 4-16 www.ni.com
Figure 4-8. SCXI-1520 to SCXI-1314 Quarter-Bridge Connection
Quarter-Bridge Configuration I
Quarter-Bridge
Completion Resistor
+
Voltage Excitation and
Half-Bridge Completion
Network Enabled
R
1
R
2
R
L
R
L
R
3
V
EX
+
S+
P+
QTR
Quarter-Bridge Configuration II
+
Voltage Excitation and
Half-Bridge Completion
Network Enabled
R
1
R
2
R
g
(dummy)
R
L
R
L
R
L
V
EX
+
S+
P+
P
1+
4V
r
GF (1 + 2V
r
)
R
L
R
g
1+
4V
r
GF (1 + 2V
r
)
R
L
R
g