Do you have a question about the natus Olympic Brainz and is the answer not in the manual?
Brand | natus |
---|---|
Model | Olympic Brainz |
Category | Medical Equipment |
Language | English |
Provides a step-by-step guide for system setup and patient prep, allowing staff to start monitoring quickly.
Allows quick access to information when it is needed most.
Simplifies patient hook-up and provides additional data with cross-cerebral, left/right hemisphere, and up to 3-channel monitoring.
Software for reviewing and analyzing recorded CFM data on a personal computer.
Offers remote viewing of active or completed recordings from any location.
User-customizable, time-stamped markers for efficient review and cross-collaboration.
Facilitates file management by increasing transfer speed.
Simplifies charting and record keeping by allowing printing onto standard paper.
Enables data management even when not connected to the hospital network.
Optional software packages available for the BRM3 Brain Monitor.
Physical dimensions of the Touchscreen Monitor, DAU, Power Supply Unit, and Roll Pole.
Weight specifications for the Touchscreen Monitor, DAU, Power Supply Unit, and Roll Pole.
Details of the color TFT LCD touchscreen display, including resolution.
Specifies the maximum load capacity of the accessory basket.
Details the power supply unit, input voltage, and output voltage.
Information on battery backup time and recharge cycles before replacement.
Automatic setting for rejecting artifacts from the signal.
Sensitivity level for maximum DAU output.
The range of signal amplitude the system can measure.
The frequency at which waveform and impedance data are updated.
User-selectable markers for annotating events during recordings.
Automatic check for sensor impedance.
Specific frequencies checked for signal integrity.
Filter settings for aEEG data, specified in dB/decade.
Percentage of EEG power spectrum within a specific frequency band.
Parameters calculated by the system, including aEEG, intensity, and SEI.
Available modes for displaying EEG data, including real-time and trends.
Frequency range for the DAU's band pass filter.
Frequency range for the DAU's high pass filter.
Type of ADC used and its conversion process.
Rate at which analog signals are sampled by the DAU.
Bit resolution of the digitized signal.
Electrical impedance of the DAU input.
Maximum allowable DC offset at the input.
Maximum noise level for the DAU.
Ability of the DAU to reject common mode signals.
Overall bandwidth of the DAU signal processing.
Temperature and humidity ranges for device operation.
Temperature and humidity ranges for shipping and storage.
List of international standards the device complies with.
List of national standards the device complies with.
Device classification indicating basic electrical protection.
Classification of the applied part for electrical safety.
Indicates the device is designed for continuous use.
Warning regarding use in flammable atmospheres.
Part number for the main BRM3 Brain Monitor unit.
Part numbers for accessories specific to North America.
Part numbers for accessories specific to the UK.
Part numbers for accessories specific to New Zealand/Australasia.
Part numbers for accessories in West Europe (excl. UK/Spain).
Part numbers for accessories specific to Denmark.
Part number for the complete BRM3 Roll Pole assembly.
Part number for a box of 20 neonatal sensor sets.
Part number for a box of 10 sensor adaptor sets.
Part number for the sensor application kit.
Part number for NuPrep Skin Preparation Gel tubes.
Part number for a box of 10 skin markers.
Part number for a bag of 10 wrap-hats.
Part number for the lithium-ion battery backup pack.
Part number for the printer mounting bracket.
Contact information for Natus Medical Customer and Technical Service in the US.
Contact information for GE Healthcare Customer Service in the UK.
Contact information for BrainZ Instruments in Australia and New Zealand.