EasyManua.ls Logo

NCR 7800 - Parameters - 1; Baud Rate; Parity; Stop Bits and Character Length

NCR 7800
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
563DUDPHWHUV
8VHUV*XLGH 
RS-232 Parameters - 1
Contains four of the parameters required for RS-232
communications. You can select the Baud Rate, Parity, Stop
Bits and Character Length, and Handshake Options.
The Baud Rate parameter contains seven baud rate selections:
300, 600, 1200, 2400, 4800, 9600, and 19200. Scan the
appropriate
Hex
0
through
Hex
6
tag to set the desired baud
rate. The default is 9600 baud.
Five parity selections are available: Odd, Even, Mark, Space,
and None. For 7-bit characters, bit 8 is the parity bit; for 8-bit
characters, bit 9 is the parity bit. Choosing no parity and 7-bit
character length results in sending two stop bits. Two stop bits
must also be received. Scan the appropriate
Hex
0
through
Hex
4
tag to select the desired Parity. The default is Odd
parity.
Contains four selections:
1 Stop Bit and 7-Bit Character length (0)
1 Stop bit and 8-Bit Character length (1)
2 Stop Bits and 7-Bit Character length (2)
2 Stop Bits and 8-Bit Character length (3)
Choosing no parity and 7-Bit Character results in sending two
stop bits. Two stop bits must also be received. If you select 8-
Bit Character length and parity, only one stop bit is sent. Scan
the appropriate
Hex
0
through
Hex
3
tag to set the Stop Bits
And Character Length. The default is 1 Stop Bit and 8-Bit
Character length.
Baud Rate
Parity
Stop Bits and
Character Length

Table of Contents