8 Diagnostics
Serial Ports Test
SelectSerial Ports (4)andpress[Enter].Theterminalserialportinformationis
displayed.
Forexample:
RS-232 Serial Ports
Serial Port #1 is configured at Port=0x3f8 and IRQ=4
Serial Port #2 is configured at Port=0x2f8 and IRQ=3
Serial Port #3 is configured at Port=0x3e8 and IRQ=11
Serial Port #4 is configured at Port=0x2e8 and IRQ=10
Note: The information above is how Diagnostics is currently
configured. It may or may not match how the BIOS or hardware is
configured. If a test fails, please check the BIOS and/or
hardware settings to ensure the proper configuration is being
tested.
1)Change Serial Port Configuration (Diagnosic operation only)
2)Test a Serial Port (Serial Turnaround Plug required)
0)Exit RS-232 Serial Ports
Select:
Fromthismenuyoucanchangetheserialportconfigurationfordiagnosticpurposes
ortestaserialport(SerialTurnaroundPlugrequired).
System Information (CPU, DMI, etc.) Test
SelectSystemInformation(CPU,DMI,etc.)(5)andpress[Enter].Theterminal
informationisdisplayed.
Forexample:
Terminal Information
Terminal:7601-1000-8800
Serial Num:50-12345678
UUID: 00020003-0004-0006-000700080009
BIOS Version:NCR BIOS 6.2.2.0
CPU Version:Genuine Intel(R) CPU 575 @ 2.00GHz
CPU Speed:1995.109 MHz
0) Exit Terminal Information
Select: