Document Revision 1 Electra Elite IPK II
3 - 14 Equipment
An example is shown below:
H
+5V
Five ESIB(8)-U10 ETUs multiplied by a table value of 21 is 105 points toward a
possible 1000 (895 points remaining).
H
-24V
Five ESIB(8)-U10 ETUs multiplied by a table value of 83 is 415 points toward a
possible 1000 (585 points remaining).
Table 3-4 KSU Power-Based Calculator Chart
Package Name
Power Consumption
Number of
ETUs
Equivalent Total Power
Point
+5V -24V +5V -24V
Common
CPUII( )-U10 ETU 200 0
CF ETU 7 0
EXP-U10 ETU 6 0
MOD-U10 Unit 25 0
Trunk
BRT(4)-U( ) ETU 67 0
COI(4)-U10 ETU 48 5
COI(8)-U10 ETU 82 9
COID(8)-U( ) ETU 55 9
COIB(4)-U20 ETU 29 5
COIB(4)-U30 ETU 29 5
COIB(8)-U30 ETU 54 9
DID(4)-U( ) ETU 24 30
DTI-U10/20/30 ETU 84 0
DTI-U40 ETU 73 0
IAD(8) ETU 31 110
TLI(2)-U( ) ETU 15 10
Station
CNF(16)-U20 ETU 17 52
ESI(8)-U( ) ETU 21 83
ESIB(8)-U10 ETU 21 83
ESIB(8) plus ESIE(8)-U10 ETU
(16 Ports)
32 166