EasyManua.ls Logo

NEC ELECTRA ELITE IPK II - Section 8 Network and Control

NEC ELECTRA ELITE IPK II
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document Revision 1 Electra Elite IPK II
5 - 14 Hardware Specifications
SECTION 7 OUTSIDE LINE TYPES
The following outside lines can be used with the Electra Elite IPK II system.
J
2-wire, Loop Start or Ground Start Trunks
J
2-wire, 2-way DID Lines (Dial Pulse or DTMF)
J
4-wire, E&M Tie Lines (Type I or V, Dial Pulse, or DTMF)
J
Digital Trunk T1/FT1 (Loop Start, Ground Start, Tie Line (E&M), or DID
Signaling)
J
ISDN-BRI Trunks
J
ISDN-PRI Trunks
J
VoIP Trunks (Internet Protocols)
SECTION 8 NETWORK AND CONTROL
8.1 Transmission, Network, and Control Specifications
8.1.1 Transmission
H
Data Length:
From Multiline Terminal to ESI(8)-U( ) ETU: 23 bits
From ESI(8)-U( ) ETU to Multiline Terminal: 23 bits
H
Data Transmission Rates:
Between ESI(8)-U( ) ETU and Multiline Terminal: 184K bps
(voice and signaling)
H
Scanning Time for each Multiline Terminal: 32 ms.
8.1.2 Network
Time Division Multiplexing (TDM) allows transmission of a number of
separate data and voice simultaneously over one communications
medium. The information below indicates the specifications the
Electra Elite IPK II system uses for switching, clock, data bus,
timeframe.
H
TDM Switching: PCM (µ Law)
H
TDM Clock: 2.048 MHz
H
TDM Data Bus: 8 bit
H
TDM Timeframe: 125 µs.

Table of Contents

Other manuals for NEC ELECTRA ELITE IPK II

Related product manuals