EasyManua.ls Logo

NEC ELECTRA ELITE IPK II - Control

NEC ELECTRA ELITE IPK II
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electra Elite IPK II Document Revision 1
General Description Manual 5 - 15
8.1.3 Control
This section indicates the speed or capacity.
H
Control: Stored program with distributed processing
H
Central Processor: 32-bit microprocessor
H
Clock: 25 MHz
H
Interface ETU: 8-bit or 16-bit microprocessor
H
Optional ETUs: 16- or 32-bit microprocessor
H
Multiline Terminal (TDM): 8-bit microprocessor
H
Multiline Terminal (IP): 32-bit microprocessor
H
IP Adapter: 32-bit microprocessor
H
Attendant Console: 4-bit microprocessor
H
SLT Adapter: 4-bit microprocessor
8.1.4 Electra Elite IPK Terminals and Equipment
The voltage, current, ring signal information for the Electra Elite IPK
Multiline Terminals, Single Line Telephone equipment, and AP(A)-R/
AP(R)-R Units is listed below.
H
Multiline Terminal
Voltage: -11 ~ -26 Vdc
Maximum Current: 250 mA
H
Single Line Telephone
Standard 2500 Set: 500 type network
Nominal Current: 35 mA
Ring Signal: 56 Vac RMS @ 20 Hz
H
SLTII(1)-U( ) ADP
Standard 2500 Set: 500 type network
Nominal Current: 30 mA
Ring Signal: 56 Vac RMS @ 20 Hz
Acoustical characteristics meet Electronic Industry
Association (EIA) standard proposal SP-1286 and
standard EIA RS-470.

Table of Contents

Other manuals for NEC ELECTRA ELITE IPK II