EasyManua.ls Logo

NEC ELECTRA ELITE IPK II - Table 5-7 Power Consumption; Table 5-8 Fuse Replacement; Table 5-9 Weights and Dimensions; Power Supply Consumption

NEC ELECTRA ELITE IPK II
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document Revision 1 Electra Elite IPK II
5 - 6 Hardware Specifications
4.2 Power Supply Consumption
When replacing fuses, refer to the specifications in Table 5-8 Fuse
Replacement.
SECTION 5 ENVIRONMENTAL CONDITIONS
5.1 Temperature
H
Operating: +32°F ~ +104°F (0°C ~ 40°C)
H
Recommended Long Term: +50°F ~ +90°F (10°C ~ 32.2°C)
5.2 Humidity
H
Operating: 10% ~ 90% noncondensing
5.3 Weights and Dimensions
Table 5-9 Weights and Dimensions provides weights and dimensions for the
units, ETUs and KSUs.
Table 5-7 Power Consumption
KSU
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
Basic KSU – B64-U20 KSU 2.5 A 120 230
Basic KSU + Expansion KSU 5.0 A 240 460
Basic KSU + 2 Expansion KSUs 7.5 A 360 690
Table 5-8 Fuse Replacement
Unit
Fuse
Number
Specifications Description Dimensions
P64-U( ) PSU F1 125V, 6.0A AC Input 1/4” x 1 1/4”
P64-U( ) PSU F101 250V, 10A Battery Input 1/4” x 1 1/4”
All fuses are normal blown glass tube.
Do not use slow blow fuses. Replace with a fuse of the
same type and rating.