Document Revision 1 Electra Elite IPK II
5 - 6 Hardware Specifications
4.2 Power Supply Consumption
When replacing fuses, refer to the specifications in Table 5-8 Fuse
Replacement.
SECTION 5 ENVIRONMENTAL CONDITIONS
5.1 Temperature
H
Operating: +32°F ~ +104°F (0°C ~ 40°C)
H
Recommended Long Term: +50°F ~ +90°F (10°C ~ 32.2°C)
5.2 Humidity
H
Operating: 10% ~ 90% noncondensing
5.3 Weights and Dimensions
Table 5-9 Weights and Dimensions provides weights and dimensions for the
units, ETUs and KSUs.
Table 5-7 Power Consumption
KSU
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
Basic KSU – B64-U20 KSU 2.5 A 120 230
Basic KSU + Expansion KSU 5.0 A 240 460
Basic KSU + 2 Expansion KSUs 7.5 A 360 690
Table 5-8 Fuse Replacement
Unit
Fuse
Number
Specifications Description Dimensions
P64-U( ) PSU F1 125V, 6.0A AC Input 1/4” x 1 1/4”
P64-U( ) PSU F101 250V, 10A Battery Input 1/4” x 1 1/4”
All fuses are normal blown glass tube.
Do not use slow blow fuses. Replace with a fuse of the
same type and rating.