SECTION 4 POWER REQUIREMENTS
The power supply inputs and the power consumption specifications for the Electra
Elite IPK II are listed below.
4.1 Power Supply Inputs
The AC input (P64-U( ) PSU) requirements for the Electra Elite IPK II are listed
below:
H
117 Vac ± 10%
H
60 Hz ± 10%
H
Single Phase
H
7.5A circuit
H
A dedicated outlet, separately fused and grounded.
Table 5-5 Cable Connection Between the Analog Port and the Single Line
Equipment
Connected Equipment Cable
Maximum Feet from Connected
Equipment to Telephone
AD(A)-R or AD(A)-2R Unit Twisted Pair 10 feet
ADA(2)-W Unit Twisted Pair 10 feet
AP(A)-R or AP(R)-R Unit Twisted Pair 50 feet
APA-U Unit or APR-U Unit Twisted Pair 50 feet
OPX(2)-U( ) ETU Twisted Pair 1,600 ohms
SLI(4)/(8)-U( ) ETU Twisted Pair 300 ohms
SLTII(1)-U( ) ADP Twisted Pair 50 feet
Mixing digital and analog ports through the same 25-pair cable runs is not recommended.
Table 5-6 Cabling Requirements
Connected Equipment Cable
Music on Hold and Background Music Sources Hi-Fi Shielded Audio Cable
External Amplifier Hi-Fi Shielded Audio Cable
ITH Cabling
Cat 5 Straight Data Network
Cable - 100 meters maximum