Document Revision 1 Electra Elite IPK II
3 - 16 Equipment
An example of KTS Configuration with a Basic and Expansion Cabinet using the
Calculator Chart is shown below.
Optional
BSU(4M)-U20 ETU 77 47
BSU(2S)-U20 ETU 35 26
BSU(6S)-U20 ETU 47 69
CCH(4)-U( ) ETU 50 0
HUB-U10 ETU 250 0
VMP( )-U40 ETU 55 96
Total Points XX XXX XXX
Table 3-4 KSU Power-Based Calculator Chart (Continued)
Package Name
Power Consumption
Number of
ETUs
Equivalent Total Power
Point
+5V -24V +5V -24V
SAMPLE CALCULATION USING KSU POWER-BASED CALCULATOR CHART
Package Quantity Total Power Consumption +5V
value from Chart
Total Power Consumption -24V
value from Chart
Basic Cabinet
CPUII( )-U10 ETU 1 200 0
ESIB/E(8)-U10 ETU 3 96 498
ESIB(8)-U10 ETU 1 21 83
SLIB(4)-U10 ETU 3 90 51
SLIE(4)-U( ) ETU 3 51 36
CTP(8)-U10 ETU 1 120 288
Totals 10 578 956
Expansion Cabinet
EXP-U10 ETU 1 6 0
DTI-U30 ETU 1 84 0
DTI-U40 ETU 1 73 0
CCH(4)-U10 ETU 1 50 0
ESIB/E(8)-U10 ETU 4 128 664
COIB(4)-U30 ETU 1 29 5
Totals 9 370 669