CHAPTER 3 ND-45383 (E)
Page 76
Revision CD 1.0
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
Note 6: Switch setting for Loop-Back Test
SW3-1 SW3-2
When loop-back test is not performed : OFF OFF
(Normal setting)
When setting the DLI to Local Loop-Back Check : ON OFF
When setting the DLI to Remote Loop-Back : OFF ON
When setting the DLI to Remote Loop-Back Check : ON ON
Note 7: Switch setting specifying BL lamp indications
SW3-7 SW3-8
The BL lamp indicates the status of No. 0 through : OFF OFF
No. 7 channel
The BL lamp indicates the status of No. 8 through : ON OFF
No. 15 channel
The BL lamp indicates the status of No. 16 through : OFF ON
No. 23 channel
The BL lamp indicates the status of No. 24 through : ON ON
No. 29 channel
SYMBOL CIRCUIT CARD
DLI PA-DAIA