3-2 Equipment
Table 3-3 Battery Mount Equipment List
Equipment Name Equipment Description
CHS2UG B SMALL BATT BOX Short-term battery box for 3-slot chassis
Backup Time – 10 minutes
CHSG LARGE BATT BOX Long Term battery box for CHS1UG-US and CHS2UG-US Chassis
Cable between batteries – 9.06in/230mm
Fuse Unit to Batteries – 18.11ln/460mm
Cable from chassis to battery box – 81.1in/2060mm
CHS2UG BATT MTG KIT Battery Mount for CHS2UG-US Chassis
Backup time – 10 minutes
CHSGW SMALL BATT SET Short-term battery set for 3-slot chassis
CHS LARGE BATT SET Long term battery set
(3) 12V 7Ah SLA Batteries with Faston 187 terminals
CHS2UG INT BATT SET Internal battery set for CHS2UG-US chassis
12V 2.3Ah SLA Battery with Faston 187
Table 3-4 Blade Equipment List
Equipment Name Abbreviations Equipment Description
PZ-BS10 BUS0 Expansion Chassis Interface Unit, 3-jack
GPZ-BS11 BUS1 Expansion Chassis Interface Unit, 1-jack
GCD-8DLCA DLC 8-port Digital Station Interface
GPZ-8DLCB DLCDB 8-port Digital Station Interface on GCD-8DLCA
GCD-16DLCA DLC 16-port Digital Station Interface
GCD-4COTB COT 4-port Loop/ground Start Trunks
GPZ-4COTF COTDB 4-port Loop/ground Start Trunks on GCD-4COTB, GCD-LTA
GCD-4LCA LC 4-port Single Line Telephone Interface
GPZ-4LCA LCDB 4-port Single Line Telephone Interface on GCD-4LCA and
GCD-8LCA
GCD-8LCA LC 8-port Single Line Telephone Interface
GPZ-8LCE LCDB 8-port Single Line Telephone Interface on GCD-4LCA and
GCD-8LCA
GCD-2BRIA BRT 2 Basic Rate Interface
GPZ-2BRIA BRTDB 2 Basic Rate Interface on GCD-2BRIA, for SV9100 can also
be mounted on the GCD-LTA blade
GCD-PRTA PRT 1 Primary Rate Interface
GCD-CCTA CCT Common Channel Interoffice Signaling Trunk Interface/
Common Channel Handler