Issue 2.0
SV9100 General Description Manual 5-17
SECTION 3 TRAFFIC CAPACITY
Table 5-14 Traffic Capacity provides information about the traffic capacity for the
basic system package and expanded system package.
The GCD-CP10 provides:
400 trunk ports maximum
896 extension ports maximum
896 ports digital/IP extensions maximum
368 analog ports maximum
ITZ-12DG-3 TEL
Class 3 230mA 11.04W 450mA 10.8W 102mA 4.9W 192mA 4.62W
ITZ-24DG-3 TEL
Class 3 230mA 11.04W 450mA 10.8W 102mA 4.9W 192mA 4.62W
Label Indication:
IP Value – Maximum watts when adding options or modular upgrades.
IP Value – Maximum watts when ITZ-12D-3 TEL is changed to ITZ-8LD-3 TEL or ITZ-24D-3 TEL.
Table 5-12 IP Terminal Power Factor Chart – DT800 (Continued)
IP
Terminal
IEEE802.3
af
Class
Label Indication
(Maximum Current with All Options)
Maximum Current Without Options
48VDC 24VDC 48VDC 24VDC
Table 5-13 IEEE802.af Class Specifications
IEEE802.3af Minimum Maximum
Class 4 – –
Class 3 6.49W 12.95W
Class 2 3.84W 6.49W
Class 1 0.44W 3.84W
Class 0 0.44W 12.95W
Table 5-14 Traffic Capacity
Traffic Capacity Basic System Package
Expanded System
Package
Traffic Capacity (GCD-CP10) 9200 BHCA (Maximum) 9200 BHCA (Maximum)
4800 Busy-Hour Call Attempts (BHCA) is based on a 176Trunk/240 station
configuration.