EasyManua.ls Logo

NEC Xen Topaz - Page 206

NEC Xen Topaz
390 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 - 198 Features
NEC Business Solutions Ltd XEN Topaz
Doc. No. 8846 - Release 2.0
April 2005
Assign each extension a Calling Party Number (maximum 16 digits per
entry). The calling number is the subscriber number of the dial-in num-
ber. When a call is made by an extension which does not have an
Extension Calling Number assigned (Program 21-12), the system sends
the calling number for the ISDN trunk defined in Program 21-13. Note: If
the Calling Party Number is assigned in both Programs 21-12 and 21-
13, the system sends the data in Program 21-13.
22-02-01: Incoming Call Trunk Setup
Assign the incoming trunk type for each trunk. There is one item for each
Night Service Mode.
22-09 : Incoming Call Setup – DID Basic Data Setup
For each trunk group, define the basic setting of Dial-In incoming calls
for each trunk group.
22-09-01 : Expected Number of Digits from Telco (1-8)
22-09-02 : Received Vacant Number Operation (Disconnect, Transfer)
22-09-03 : Sub-addressing Mode (Extension Number specify, DID Con-
version Table)
22-09-04 : DID Receiving Mode for ISDN (Enbloc Receiving, Overlap
Receiving)
22-09-05 : Local Code Digits (0-15)
22-09-06 : Local Code (Max. 16 digits)
22-09-07 : Pilot Code (1 digit, 0-9)
22-09-08 : T302 Time-out Operation (Disconnect, Transfer)
22-11-01: DID Translation Table Number Conversion
Specify for each Translation Table entry (2000):
1 The digits received by the system (eight max.)
2 The extension the system dials after translation (24 digits max.)
3 The name that should show on the dialled extension’s display when it
rings (twelve characters max.)
4 The Transfer Target - 1 and 2. If the Transfer Targets are busy or receive
no answer, those calls are transferred to the final transfer destination (Pro-
gram 2-10).
5 Operation mode
Assigning an ISDN Interface as an S-Bus Extension
In the following example, BRI Interface 1 will be assigned as an S-Bus extension.
Connected to this S-Bus port may be a video conference unit, G4 fax machine or other
ISDN device. Switch and Jumper settings referred to are located on the 2/4BRIU card.
Setup:
1. Set switch SW102 = S.
2. Set switch SW100 = ON.
3. Set both jumpers of CN102 = ON.
4. Assign Program 10-03-01 for BRI Interface 1 = S-Point.
5. If the cable length to the S-Bus device is between 200m and 500m, set Program 10-03-06 =
0. Otherwise leave at default (1).

Table of Contents

Other manuals for NEC Xen Topaz

Related product manuals