EasyManua.ls Logo

Necta Colibri - Cleaning the Water Supply Tank; Cleaning the Sugar Release Device; Cleaning the Waste Trays

Necta Colibri
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
© by NECTA VENDING SOLUTIONS SpA 0012 Colibrì
CLEANING THE WATER SUPPLY TANK
(OPTIONAL)
For machines equipped with a water tank inside the
support cabinet, at least once a week, such tank must be
sanitised with the chlorine-based detergent used for the
mixers.
CLEANING THE SUGAR DISPENSER
For models with sugar dispensed directly into the cup, the
sugar dispensing system must be cleaned periodically
using hot water (see Fig. 7) proceeding as follows:
- release the return spring;
- lift the flexible lever to free the pin;
- remove the pin and the dispensing spout;
- after cleaning, thoroughly dry all parts and reinstall
them in the reverse order.
CLEANING THE WASTE CONTAINERS
The waste containers can be easily removed even with the
door closed (see Fig. 8) permitting quick emptying and
cleaning.
The coffee container capacity is greater than that of the
waste container (if the support cabinet is not used).
The machine control software indicates on the display that
the maximum number of coffee selections has been reached
with the message "Waste container full".
After a few further selections the machine will lock.
The waste container must be emptied without switching
the machine off, to allow the software to detect the opera-
tion.
Fig. 8
1 - Coffee waste container
2 - Dispensing compartment drip tray
Fig. 7
1 - Sugar dispensing spout
2 - Pin
3 - Flexible lever
4 - Return spring
With the coffee waste container removed, the machine is
still available for instant drink selections but indicating the
message "Insert waste container" on the display.
The selection counters are reset with the door closed doing
as follows:
- press button 8 for 2 seconds
The display will show the request to enter the password;
- press one after the other buttons 4231 to reset the
counters.

Table of Contents

Other manuals for Necta Colibri

Related product manuals