7 Troubleshoot PowerRouter • Solar Inverter • Installation manual
36
EN
P111-S Soft The PowerRouter was not able to
configure the 3-phase sensor
Make sure the 3-phase sensor is connected
properly
Make sure the 3-phase sensor is not in the locked
position
Restart the system (section 7.6.1)
P115-H Hard The PowerRouter cannot function
correctly because some hardware
modules were not detected
Contact your dealer if this error occurs
P118-H Hard The installation wizard failed. Restart the system (section 7.6.1)
Run the installation tool or install wizard again
Contact your dealer if this error occurs frequently
G001-S
G037-S
Soft The internal temperature of the
grid module (G) is too high
The output power of the module is
reduced
Check the PowerRouter airflow (section 7.6.2)
Once the module cools down the error will
disappear and normal operation will resume
Contact your dealer if this error occurs frequently
G002-S Soft An overvoltage occurred on the
power backbone. The grid module
(G) will be temporarily turned off
Once the voltage drops below the safe level the
error will disappear and normal operation will
resume
Contact your dealer if this error occurs frequently
G003-S Soft An undervoltage occurred on the
power backbone. The grid module
(G) will be temporarily turned off
(e.g. the load on the local out is
higher than the power available in
the PowerRouter)
Make sure the loads on the local out are turned off
After one minute the error will disappear and normal
operation will resume
Contact your dealer if this error occurs frequently
G007-S Soft The voltage level on the local out
is too high in a situation where no
voltage is expected
If this error occurs during installation make sure the
grid is connected to the “AC GRID” connection
When this error occurs during normal operation an
error has occurred in connection with the anti-
islanding safety requirements
Restart the system (section 7.6.1)
Contact your dealer if this error occurs frequently
G011-S Soft An undervoltage occurred on the
local out. The local out will be
temporarily turned off.
Make sure the loads on the local out are turned off
After one minute the error will disappear and normal
operation will resume
Contact your dealer if this error occurs frequently
G012-S Soft An overvoltage occurred on the
local out. The local out will be
temporarily turned off (e.g. a very
high load connected to the local
out was suddenly disconnected)
Make sure the loads on the local out are turned off
After one minute the error will disappear and normal
operation will resume
Contact your dealer if this error occurs frequently
G013-H Hard A short circuit was detected on
the PowerRouter local out
Make sure the loads on the local out are turned off
Check the wiring connected to the local out for a
short
Restart the system (section 7.6.1)
G015-S Soft There was an internal
communication error within the
PowerRouter
After one minute the error will disappear and normal
operation will resume
Contact your dealer if this error occurs frequently
G023-H Hard The local out output was
overloaded
Turn off the loads connected to the PowerRouter
Restart the system (section 7.6.1)
G025-H Hard See P027-H

Table of Contents

Other manuals for Nedap PowerRouter

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nedap PowerRouter and is the answer not in the manual?

Nedap PowerRouter Specifications

General IconGeneral
BrandNedap
ModelPowerRouter
CategoryInverter
LanguageEnglish

Related product manuals