PowerRouter • Solar Inverter • Installation manual 7 Troubleshoot
37
EN
G028-H Hard An error occurred on one of the
internal voltage supplies of the
grid module (G)
• Restart the system (section 7.6.1)
• The system should recover from the error after the
restart
• Contact your dealer if this error occurs frequently
G029-S Soft The grid module (G) start-up
procedure failed
• After one minute the error will disappear and normal
operation will resume
• Contact your dealer if this error occurs frequently
G031-H Hard There was an overpower on the
output of the PowerRouter
• Turn off the loads connected to the PowerRouter
• Restart the system (section 7.6.1)
G034-H Hard See P092-H
G036-H Hard See P098-H
G039-S Soft The output power of the grid
module (G) has been reduced
because the grid frequency was
too high
• The error will disappear and normal operation will
resume when the grid frequency is within approved
limits
G040-S Soft The output power of the grid
module (G) has been reduced
because the grid voltage was too
high
• The error will disappear and normal operation will
resume when the grid voltage is within approved
limits
G041-S Soft The output power of the grid
module (G) has been reduced
because the 10 minute average of
the grid voltage was too high
• The error will disappear and normal operation will
resume when the 10 minute average of the grid
voltage is within approved limits
G043-H Hard Error occured in anti-islanding
settings.
• Restart the system (section 7.6.1)
• Run the installation wizard or tool again and select
country.
S002-S
S023-S
Soft The internal temperature of the
solar module (S) is too high
The output power of the module
has been reduced
• Check the airflow of the PowerRouter (section 7.6.2)
• When the module cools down the error will
disappear and the normal operation will resume
• Contact your dealer if this error occurs frequently
S004-S Soft The solar string voltage
connected to one or both of the
inputs exceeds 600 volts
• Check the solar panel configuration and wiring
• The error will disappear when the voltage on both
strings drops below 600 volts
S005-S Soft An overvoltage occurred on an
internal bus of the solar module
(S)
• The error will disappear when the voltage drops
below the limit
• Contact your dealer if this error occurs frequently
S007-S Soft An overcurrent occurred on an
internal circuit of the solar module
(S)
• After ten minutes the error will disappear and
normal operation will resume
• Contact your dealer if this error occurs frequently
S013-S Soft The output power of the solar
panels exceeds 6000 watts
• This error will disappear when the power drops
below 6000 watts
• Contact your dealer if this error occurs frequently
S016-S Soft There was an internal
communication error within the
PowerRouter
• The error will disappear automatically and normal
operation will resume
•
C
ontact your dealer if this error occurs frequently
S019-H Hard See P092-H
S021-H Hard See P098-H
S024-S Soft Problem with the onboard supply
voltage, or the SOlar boost limiter
is activated.
• The system will recover automatically.
• Contact your dealer if this error occurs frequently