Nedap SmartFlow / Installation manual
Version 01.001 / 2021 / EN
36
Dairy Farming
Figure6:Pouring water in the milk inlet tube
4. Wait for at least 3 minutes.
5. Repeat step 3 and 4 four times
Caution
The total Zero Point test session consists of five consecutive runs, with at least 3-minute intervals.
6. Check if Velos has accepted the results of all 5 test runs:
a. If less than 5 test runs are accepted: Run the missing number of test runs.
b. If all test runs are not accepted: Repeat the complete Zero Point test.
7. De-install the air compressor.
8. Reconnect the milk inlet tube to the milk claw.
Zero Point test results:
1. When the Zero Point test is completed, the result passed or failed is shown immediately.
2. PASSED: Zero Point test result is in range: No further action is needed, the result is stored and can be
checked in the report.
3. FAILED: Zero Point test result is not in range: Check the SmartFlow in the milking parlor for technical
issues.
a. The SmartFlow is technically fine: Select one of the following options to proceed:
Cancel the new Zero Point test results.
Restart the Zero Point test.

Other manuals for Nedap SmartFlow

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nedap SmartFlow and is the answer not in the manual?

Nedap SmartFlow Specifications

General IconGeneral
BrandNedap
ModelSmartFlow
CategoryFarm Equipment
LanguageEnglish

Related product manuals