UPASS REACH | INSTALLATION GUIDE
Connections
10/35
3.2 WIRE CONNECTIONS
Wire connections to the uPASS Reach are user friendly spring cage terminal
connectors.
Connection procedure with spring cage terminal connectors.
1 Strip wire lead for about 9 mm (0.35
inch).
2 Push the screwdriver straight down
to release the spring cage. Use a
slotted, narrow-head screwdriver.
3 Insert the wire lead into the wire
terminal.
4 Remove the screwdriver, this clamps
the wire.
5 Gently pull on the installed wire to
make sure the connection is reliable.
Figure 9: Wiring detail
See appendix A for recommended maximum and minimum conductor cross sections
and for the recommended wire stripping length.
3.3 POWER SUPPLY
The UF reader requires DC power supply in the range from 12 – 24V. Maximum
current consumption is 1A @ 12VDC, 0.5A @ 24VDC.
Connections:
Wiring is normally done
without ferrules. However,
it is possible to use ferrules,
provided that they are
properly crimped.