UPASS REACH | INSTALLATION GUIDE
DIP Switch Settings
19/35
4 DIP SWITCH SETTINGS
The DIP-switches are located behind the service cover. Switches SW1-1 through
SW1-4 are described below.
The switches SW2-1 through SW2-8 are reserved for the TRANSIT compatible
processor (e.g. P61, P81 or Q70). Please refer to the corresponding firmware manual
for details.
1
2
3
4
5
6
7
8
1
2
3
4
Figure 22: DIP-switches
4.1 COMPATIBILITY MODE (SW1-1)
Compatibility mode selection. Enable UHF processor or TRANSIT compatible
processor (e.g. P61, P81 or Q70).
This selection determines the enabled communication protocol and the relay output
control. Remember that the TRANSIT compatible processor only operates in
combination with NEDAP UHF XS formatted tags.
ON
1
2
3
4
SW1-1
UHF processor
ON
1
2
3
4
SW1-1
TRANSIT compatible processor (e.g.
P61, P81 or Q70)
4.2 RS232 / RS422 SELECTION (SW1-2)
On-board RS232 or RS422 interface selection.
RS232 connection details are described in chapter 3.4.4 (page 13).
RS422 connection details are described in chapter 3.4.5 (page 14).
ON
1
2
3
4
SW1-2
On-board RS232 interface enabled
ON
1
2
3
4
SW1-2
On-board RS422 interface enabled