UPASS REACH | INSTALLATION GUIDE
Connections
9/35
3 CONNECTIONS
3.1 CABLE CONNECTIONS
Cable connections to the uPASS Reach are made using the EMC cable glands.
Shielded cable shall be used for all connections including the DC-supply
connection.
Assembly instructions:
1 Push the cap nut
(1), seal insert (2)
and gland contact
socket (3) onto the
cable.
2 Cut back the outer
sheath to desired
length.
3 Bend over the
screen braiding (4)
over the gland
contact socket and
cut back the screen
braiding as shown
in Figure 7.
1
2
3
4
Figure 7: Cable shield
4 Screw the cap nut onto
reader part until the seal
insert is pushed out of
the gland. See Figure 8.
Figure 8: Gland tightening
Correct mounting and tightening the EMC cable glands is essential for water
protection.
See appendix A for detailed information on the cable glands.