Page 28 of 28
IR commands (Advanced users)
It is also possible to send IR codes on Tx 1 and 2. Sending IR codes is only possible when con-
trolling the unit over LAN.
Before you start working with IR commands, it is important to understand that this part of the
system is intended for advanced users and requires a high level of IR code knowledge.
The IR codes that are employed conform to a commonly used format. This allows you to easily nd
IR codes from other sources than Neets, e.g. www.remotecentral.com
If you want to control continuous functions such as volume on a device, you should remember to
retransmit the IR command for as long as you want the volume to change. (Remember to wait for
the acknowledgement of sending IR command before sending the next.)
Below are the settings for the IR. For all commands, the mandatory start sequence looks like this:
NEUNIT=<A>,IR=<B>
Where <A> as default is 1, and <B> is the IR port number to use. All commands must be start-
ed with a “,” and all lines must end with a \CR
Description Syntax <X> Default <X> R/W
Data container.
The data are in RAW IR code format.
Can be copied directly from Neets Device
Editor.
DATA=<X> Up to 500
byte of date
xxxx yyyy …. zzzz R/W
Example of use: NEUNIT=1,IR=2,DATA=0000 006D 0022 0002 0155 00AB 0015 0040 0016
0015 0015 0015 0016 0040 0015 0040 0016 003F 0016 0040 0015 0015 0016 0015
0016 003F 0016 0040 0015 0015 0016 0015 0016 0015 0015 0015 0016 0040 0015
0040 0016 0015 0015 0015 0016 0015 0016 0015 0015 0015 0016 0015 0016 0015
0015 0015 0016 0040 0015 0040 0016 003F 0016 0040 0015 0040 0016 003F 0016 0040
0015 05E9 0156 0055 0016 0E3F\CR <-Sending a IR command on the Tx 2 port.