www.nektartech.com Nektar Pacer User Guide 21
Factory Restore & MIDI Implementation Chart
Factory Restore
Restoring to factory settings will revert all Pacer settings to the state they were in when you first purchased the unit.
Make sure that you backup any presets or settings that you want to retain before you restore, otherwise they get lost.
Here are the steps for restoring to factory settings:
• Make sure your Pacer is switched off.
• Press the [Preset] switch and hold it while switching power on.
• The display reads “G CFG”. Move the [Data Encoder] until it reads “RESET”.
• Press the ‘Data Encoder”. The reset will activate immediately.
• Once complete, Pacer reverts to the top level menu.
MIDI Implementation Chart
Function Tx Rx Notes
Basic
Channel
Default
Changed
1
1-16
1
1-16
Mode
Memorized
Messages
Altered
X
X
n/a
3
X
X
Note Values 0-127 0-127 Programmable
Velocity Note On 0-127 0-127
Note O X X
Aftertouch Channel O O
Pitch Bend O X
Control Change 0-119 0-127 0-127 Programmable
Program Change 0-127 X Programmable
System Exclusive O O
System Common X X
System Clock X X
Aux CC Messages 120-127 O O
X=No
O=Yes
Mode 1: OMNI ON, POLY Mode 2: OMNI ON, MONO
Mode 3: OMNI OFF, POLY Mode 4: OMNI OFF, MONO