TECHNICAL DATA
1. Transformer
24 VAC internal transformer; 20 VA, .83A for zones and logic. The
transformer can run a pump or master valve and one zone valve, maximum.
2. Surge Protection
600 watts TVS on zone outputs
9J Mov on secondaries. (see Circuit Breaker below)
3. Sensor Operation
The EZ Pro
™
Jr. is configured to operate the controller with or without a
sensor. Sensors must have normally closed connections (leads). The
factory-installed jumper wire must be in place if no sensor is used.
4. Zone Lines
The EZ Pro
™
Jr. will operate a maximum of two (2) solenoids concurrently,
providing one is the pump/master valve. Each zone output can operate one
or two solenoids.
I inrush .52A max
I hold .33A max
5. Temperature Range
Operating: -20° to +55° C (23° to 131° Fahrenheit)
Storage: -30° to +85° C (-22° to 185° Fahrenheit)
24