FOLLOW ME TELEPHONE NUMBER
The Follow Me telephone number is only used in Audible Dialling mode. (If P86E 4E or
6E are on).
The Follow Me telephone number can be programmed in User Program Mode. If
the Follow Me number is programmed, then the primary & secondary numbers are
ignored.
IF P86E 4E IS ENABLED (AUDIBLE MONITORING)
In this case, if the Follow Me number is programmed, the primary & secondary
numbers are ignored.
IF P86E 6E IS ENABLED (CONTACT ID + AUDIBLE)
The telephone numbers programmed at P70E & P71E will be used to send the mesage
to the central station. The message is also repeated in audible format to the telephone
number (if any) programmed at P00E.
PROGRAMMING SEQUENCE:
P00E existing telephone number is displayed one digit at a time
[ENTER NEW TELEPHONE No] E new telephone number is displayed one digit at a time
P00E
PROGRAM MODE LEVEL
User, Installer mode or NessComms.
FACTORY DEFAULT
No telephone numbers.
NOTES
disabled, all audible format calls are made
on telephone numbers 1 & 2.
RELATED OPTIONS
P86E 2E Contact ID format (Back to
base monitoring).
P86E 4E Audible format.
P86E 6E Contact ID + Audible Pulse.
TELEPHONE NUMBERS 1 & 2
The panel can dial up to 2 phone numbers when an event is to be transmitted to a
central monitoring station or other location. Telephone numbers may be up to 30 digits
in length.
PROGRAMMING SEQUENCE:
P70E existing telephone number is displayed one digit at a time
[ENTER NEW TELEPHONE No] E new telephone number is displayed one digit at a time
EXAMPLE: To program Telephone No.1 to be 03 1234 1234:
P 70 E 0312341234 E
TO CLEAR A TELEPHONE NUMBER
To clear a telephone number, enter the MEMORY key in place of the telephone number.
Example, to clear a Telephone Number 1 press: P70E MEMORY E
P70E, P71E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
No telephone numbers.
NOTES
calls are made on telephone number 1
and the setting of P87E 1E has no effect.
test calls are made on telephone number
1&2
number display sequence.
RELATED OPTIONS
P87E 1E Alternate Primary/Secondary
telephone numbers.
P86E 1E Disable dialler (still allows
remote up/download if programmed).
Option No. Description Default
P00E FOLLOW-ME TELEPHONE NUMBER - For audible dialling
P70E TELEPHONE NUMBER 1 - PRIMARY
P71E TELEPHONE NUMBER 2 - SECONDARY
P80E TELEPHONE NUMBER 3 - TEST CALLS
P81E TELEPHONE NUMBER 4 - CALLBACK FOR UPLOAD
P72E ACCOUNT NUMBER 1 0000
P73E ACCOUNT NUMBER 2 0000
SPECIAL CHARACTERS (Applies to all telephone Numbers)
If required, pauses, * (star) or # (hash) VF digits can be included in the dialling
sequence by using the keys in the table below.
SPECIAL CHARACTER KEY ENTRY KEYPAD DISPLAY
PAUSE (1.6sec) ARM Key 12
* (Star) HOME Key 10
# (Hash) EXCLUDE Key 11
38
NESS D8X / D16X DELUXE CONTROL PANEL – INSTALLATION MANUAL
PROGRAMMING