CONNECTION DIAGRAMS
PCB V8
8
NESS D8X / D16X DELUXE CONTROL PANEL – INSTALLATION MANUAL
RECEIVERLISTEN SERIAL
READER
PROG
INTERNAL
TAMPER
Heartbeat LED
Keypad Connection (alternative)
KEYPAD
BATTERY
RED +
AUX1
AUX2
AUX3
AUX4
+12V
0V
TAMP
+12V
+12V
+12V
0V
Z8
C
Z7
Z6
C
Z5
Z4
C
Z2
Z3
C
Z1
0V
CLK
DAT
COM
KEYPAD
RESET
STR
SIREN
BLACK
J1 LINK
&BOX TAMPER PROGRAM LINK
= Sealed, normal state
=Tamper alarm state
Powerupwith link off to enter
installer program mode
BATTERY LEADS
(supplied)
J1
Main Board Rev8
D8x or D16x
LISTEN
Audio Alerts &
dialler listen-in
diagnostics.
Requires separate
audio amp & spkr
BATTERY CONNECTION
For 12V 7Ah Backup
battery (Ness BAT210)
RECEIVER
Header for
connecting
optional Radio
Interface.
AUX
Aux
outputs 1-4
SERIAL
RS232 serial port
READER
Connection for
up to3Ness
Weigand
Also used for Ness PD
Portable Download tool.
readers.
TELEPHONE
+12V
Z16
C
Z15Z14
C
Z13Z12
C
Z10
Z11
C
Z90V
Up to2xStrobe Light (NOI-300)
Up to3xHorn Speaker,8Ohm (NOI-110)
12V DC output
N.OTAMPER SWITCH
(761-002) Colour:BLACK
Supplied with Ness siren covers
N.CTAMPER SWITCH(SWI920) Colour: WHITE
ALTERNATIVE TAMPER SWITCH WIRING
ForN.C. Tamper Switches
Zone 2
Zone 6
Zone 4
Zone 8
Zone 7
Zone 1
Zone 5
Zone 3
12V DC output for detectors.
500mAmax.
Auto Reset fuse protected.
from all 12V outputs.
+12V
(Red)
CLK (White)
DAT (Blue)T
COM (Black)
Polarity is not important for this output
BOX TAMPER SWITCH
(White) N.C. contacts
Connect to J1
1. Listen Out
2. not used
3. Common
4. +12V out
8 ohm spkr
pins 1 & 3
and connection for
output expander/s
Telephone lead (Australia only).
Connect to Mode3 socket.
END OF LINE RESISTORS
The default end of line resistor value is 2k2 (2200 Ohms). The EOL value is fully
programmable with a choice of 13 resistor values, see program option P129E.
Ness panels are supplied with 2k2 1% tolerance Metal Film resistors.
Colour code: Red, Red, Black, Brown, Brown.
NORMALLY OPEN
( DEVICESN.O.)
NORMALLY CLOSED
( DEVICESN.C.)
ZONE WIRING
Detector
Detector
Zone
C
Zone
C
Up to 3 x 12V Screamer (100-238, 100-004)
KPX keypadSATURN keypadNAVIGATOR keypad*
*NAVIGATOR keypad is compatible with D8x/D16x control
panels version 7.0 or later
Maximum 3 mixed
keypads or 4 Navigator
keypads per system.
ZONES 9-16
D16X ONLY
ZONES 1-8 D8X & D16X
17VAC
Plug Pack
Dual voltage power input.
17VAC or 20VDC
To avoid damage please connect the
correct power supply as shown.
17V AC
POWER SUPPLY
20V DC
POWER SUPPLY
Yellow/Green
To panel earth (optional)
* Optional power supply.
This power supply has positive and negative
20VDC output however the polarity is not
important in this case.
Part No. 840-054Part No. 840-029
This power supply is included with most D8x/D16x
models (Australia only).
Non-Polarity
17VAC
20VDC*
Brown
Blue
17VAC or
20VDC
POWER INPUT
NON-POLARITY
17VAC or
20VDC
POWER INPUT
NON-POLARITY

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ness D8xD and is the answer not in the manual?

Ness D8xD Specifications

General IconGeneral
BrandNess
ModelD8xD
CategoryControl Panel
LanguageEnglish

Related product manuals