ChipSHOUTER Users Manual: Fault Modes
50
stead you must first disarm the ChipSHOUTER before turning
off the trigger generation device.
Internal Faults
The device has a variety of internal faults. If these faults
become persistent it indicates a likely hardware failure
that requires repair of the ChipSHOUTER. Internal faults in-
clude:
RAM CRC error, FLASH CRC error, or firmware sig-
nature verification error.
Measured capacitor bank voltage differs from set
voltage.
Permanent failure of ability to measure tempera-
ture (sensor failure).
Input power supply (19V DC) is out of-spec, ei-
ther too high or too low. This most often occurs
if power supply browns-out during operation.
High-voltage charge circuit error (over-voltage,
over-temp, or input voltage out-of-spec).
Enclosure has been opened (interlock switch acti-
vated).