XPS-D Controller Start-Up Manual
For Split power entry version:
Terminate the provided C19 plug to an AC line cord and connect it into the
“MOTOR DRIVE” cable receptacle.
Connect a standard C13 AC line cord in the “CONTROLLER” cable receptacle.
These connections must remain accessible by the user.
Figure 14: Split power entry line connections.
WARNING
The AC mainline(s) must include a protective earth.
NOTE
Power Input: 100240 V, 60/50 Hz, 106.9 A
3.4.4 Power ON
Turn the Main Power Switch to ON (located on the Rear Panel).
For Split power entry version, turn on both AC supply lines (in any order).
There is an initial beep after power on and a second beep when the controller has
finished booting. If the controller boots properly, the second beep is happy-
sounding, otherwise the sad-sounding beep is emitted. The time between the first
and the second beeps is approx. 20 seconds.
There is also an Inhibit switch with a BNC connector in the rear of the XPS. The
Inhibit switch is directly linked by hardware to cut off motor power supply.
3.5 Connecting to the XPS
XPS supports 10/100/1000 Mbps Ethernet networking and can be accessed through:
1. Direct connection PC-to-XPS.
The Ethernet plugs “REMOTE” or “HOST” can either be used.
The plug “REMOTE” has a fixed IP address (192.168.254.254). The DHCP server
active on this plug will automatically configure the connected computer to make it
ready for communication with the XPS controller.