EasyManuals Logo

NewTek talkshow VS100 User Manual

NewTek talkshow VS100
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
51
APPENDIX E RELIABILITY TESTING
We appreciate that our products serve vital roles in the productions of our customers. Durability
and consistent, robust performance are much more than just adjectives for your business and ours.
For this reason, all NewTek products undergo rigorous reliability testing to ensure they meet or
exceed our own exacting test standards, as well as relevant criteria by various regulatory bodies
worldwide.
For TalkShow
®
VS 4000 and VS 100, the following standards are applicable:
Test Parameter
Evaluation Standard
Temperature
Mil-Std-810F Part 2, Sections 501 & 502
Ambient Operating
0°C and +40°C
Ambient Non-Operating
-10°C and +55°C
Humidity
Mil-STD 810, IEC 60068-2-38
Ambient Operating
20% to 90%
Ambient Non-Operating
20% to 95%
Vibration
ASTM D3580-95; Mil-STD 810
Sinusoidal
Exceeds ASTM D3580-95 Paragraph 10.4: 3 Hz to 500 Hz
Random
Mil-Std 810F Part 2.2.2, 60 minutes each axis, Section 514.5 C-VII
Electrostatic Discharge
IEC 61000-4-2
Air Discharge
12K Volts
Contact
8K Volts

Table of Contents

Other manuals for NewTek talkshow VS100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NewTek talkshow VS100 and is the answer not in the manual?

NewTek talkshow VS100 Specifications

General IconGeneral
BrandNewTek
Modeltalkshow VS100
CategoryTouch terminals
LanguageEnglish

Related product manuals