Control
69
FIGHTER 1320
Menu 6.2.0 Immersionheatersetti
The number of electrical steps activated is shown
with the text, x el. steps. Pressing the enter button
takes you to sub-menus where settings concerning
the connected electrical additional heater for heat
production are made. Only shown when Electricity
or Electri/Oil is selected in menu 9.1.8.
Menu 6.2.1 Immersionheater type
Here you select whether immersion heater control
shall take place in binary or linear.
Binary control means that stepping is carried out
according to the binary system and in doing so
makes it possible to control a maximum of 63 elec-
trical steps.
Linear control gives a maximum of 6 electrical
steps when stepping is carried out according to the
linear increase model.
Menu 6.2.2 Immersionheatrelays
Here you select how many relays are connected to
the electrical additional heater for heat production.
Adjustable between 1 and 6. The factory setting is
3.
Menu 6.2.3 Steps at 2h delay
The number of permitted electrical steps within 2
hours of start up. Adjustable between 0 and 63.
The factory setting is 3.
Menu 6.2.4 Quickstart el.heater
Select Yes to bypass the 2-hour electrical addition-
al heater delay
NOTE! The setting returns to No as soon as the
heat pump has implemented the action.
Menu 6.2.5 Time factor el.cass.
The time factor of the immersion heater since first
start up is shown here. The value is saved in the
microprocessor and thus is not reset even when
the heat pump is switched off using the main
power switch.
Menu 6.2.6 Return
Pressing the enter button returns you to menu
6.2.0.
6.0 External units*
U
U
U
U
U
U
U
U
N
U
U
U
U
U
U
Menu 6.1.0 Circulation pumps
Pressing the enter button takes you to the sub-
menus for the circulation pumps. Settings are made
here for internal and external circulation pumps.
Menu 6.1.1 Op-mode external cp
The operating mode for an external heating medium
pump (VBP3) is set here. Selectable options are:
Continuous: Continuous operation.
Economy: The pump is operational a specific time
per period (see menu 6.1.2 and 6.1.3), and togeth-
er with the compressor.
The factory setting is Continuous.
Menu 6.1.2 Periodtime economy
Here the period time for economy mode is set
here. This applies to heating medium pump A
(VBP-A) when Economy is selected in menu 5.4.7,
and/or the external heating medium pump (VBP3)
when Economy is selected in menu 6.1.1.
Adjustable between 5 and 120 minutes. The facto-
ry setting is 20 minutes.
Menu 6.1.3 Operati-time econom
The operating time per period for the economy
mode is selected here. This applies to heating
medium pump A (VBP-A) when Economy is select-
ed in menu 5.4.7, and/or the external heating medi-
um pump (VBP3) when Economy is selected in
menu 6.1.1. Adjustable between 1 and 120 min-
utes. The factory setting is 5 minutes.
Menu 6.1.4 Time of period Hw-cp
Here you select between which times of the day
the hot water circulation pump shall run according
to the period time (menu 6.1.5) and the operating
time (menu 6.1.6).
Menu 6.1.5 Periodtime Hw-cp
Here the period time for the hot water circulation
pump is set here. Adjustable between 10 and 60
minutes. The factory setting is 15 minutes.
Menu 6.1.6 Operatingtime Hw-cp
The operating time per period for the hot water cir-
culation pump is selected here. Adjustable
between 1 and 60 minutes. The factory setting is 3
minutes.
Menu 6.1.7 Return
Pressing the enter button returns you to menu
6.1.0.
* Only shown when the accessory in question is
connected and activated in menu 9.1.x.