In multi-installations with several heat pumps, some menus are also visible in the display on the heat pumps that are not
the main unit.
Menu 1 - Indoor climate
OVERVIEW
1.1.1 - Heating1.1 - Temperature
1.1.2 - Cooling
1
1.1.3 - Humidity
1
1.2.1 - Fan speed
1
1.2 - Ventilation
1
1.2.2 - Night cooling
1
1.2.3 - FLM cooling
1
1.2.4 - Demand controlled ventilation
1
1.2.5 - Fan return time
1
1.2.6 - Filter cleaning interval
1
1.3.3 - Room sensor settings1.3 - Room sensor settings
1.3.4 - Zones
1.4 - External influence
1.5 - Climate system name
1.30.1 - Curve, heating1.30 - Advanced
1.30.2 - Curve, cooling
1
1.30.3 - External adjustment
1.30.4 - Lowest supply heating
1.30.5 - Lowest supply cooling
1
1.30.6 - Highest supply heat
1.30.7 - Own curve
1.30.8 - Point offset
1
Consult the accessory’s Installer Manual.
MENU 1.1 - TEMPERATURE
Here, you make temperature settings for your installation’s
climate system.
If there is more than one zone and/or climate system, the
settings are made for each zone/system.
MENU 1.1.1 - HEATING
Set the temperature (with room sensor
installed and activated):
Setting range: 5 30 °C
The value in the display appears as a temperature in °C, if
the zone is controlled by a room sensor.
Caution
A slow heating system such as underfloor heating
may be inappropriate for controlling with room
sensors.
Setting the temperature (without room
sensors activated):
Setting range: -10 10
The display shows the set value for heating (curve offset).
To increase or reduce the indoor temperature, increase or
reduce the value in the display.
The number of steps the value has to be changed in order
to achieve a one degree change to the indoor temperature
depends on the climate system. One step is usually enough,
but in some cases several steps may be required.
If multiple zones in a climate system do not have activated
room sensors, these will have the same curve offset.
Set the desired value. The new value is shown on the right-
hand side of the symbol on home screen heating.
41Chapter 9 | Control - MenusNIBE S1256