MENU 7.1 - OPERATING SETTINGS
Make operating settings for the system here.
MENU 7.1.1 - HOT WATER
This menu contains advanced settings for hot water opera-
tion.
MENU 7.1.1.1 - TEMPERATURE SETTING
Start temperature
Demand mode, small/medium/large
Setting range: 5 70 °C
Stop temperature
Demand mode, small/medium/large
Setting range: 5 70 °C
Stop temp. periodic increase
Setting range: 55 70 °C
Start temp. and stop temp. demand mode, small/medi-
um/large: Here, you set the start and stop temperature of
the hot water for the different demand modes (menu 2.2).
Stop temp. periodic increase: Here, you set the stop temper-
ature for periodic increase (menu 2.4).
MENU 7.1.2 - CIRCULATION PUMPS
This menu contains sub-menus where you can make ad-
vanced circulation pump settings.
MENU 7.1.2.1 - OP. MODE HM PUMP GP1
Operating mode
Options: Auto, Intermittent
Auto: The heating medium pump runs according to the
current operating mode for S1256.
Intermittent: The heating medium pump starts approx. 20
seconds before and stops 20 seconds after the compressor.
Caution
The selection "Intermittent" is only available in in-
stallations with external supply temperature
sensor (BT25).
MENU 7.1.2.2 - PP SP. HEATING MEDIUM GP1
Heating
Auto
Alternative: on/off
Manual speed
Setting range: 1 - 100 %
Minimum permitted speed
Setting range: 1 - 50 %
Maximum permitted speed
Setting range: 80 - 100 %
Speed in wait mode
Setting range: 1 - 100 %
Hot water
Auto
Alternative: on/off
Manual speed
Setting range: 1 - 100 %
Make settings here for the heating medium pump's speed
in the current operating mode, for example in heating or hot
water operation. Which operating modes can be changed
depends on which accessories are connected.
Heating
Auto: Here, you set whether the heating medium pump is
to be regulated automatically or manually.
Manual speed: If you have opted to control the heating me-
dium pump manually, you set the desired pump speed here.
Minimum permitted speed: Here, you can restrict the pump
speed to ensure that the heating medium pump is not al-
lowed to operate at a lower speed in auto mode than the set
value.
Maximum permitted speed: Here, you can restrict the pump
speed to ensure that the heating medium pump is not al-
lowed to operate at a higher speed than the set value.
Speed in wait mode: Here, you set the speed the heating
medium pump will have in standby mode. Standby mode
occurs when heating operation is permitted but there is no
need for either compressor operation or electric additional
heat.
Hot water
Auto: Here, you set whether the heating medium pump is
to be regulated automatically or manually in hot water mode.
Manual speed: If you have opted to control the heating me-
dium pumps manually, you set the desired pump speed here
in hot water mode.