NOTE
Blocking entails a risk of freezing.
Functions that can be blocked:
hot water (hot water production). Any hot water circulation
(HWC) remains in operation.
heating (blocking of heating demand)
internally controlled additional heat
compressor
tariff blocking (additional heat, compressor, heating and
hot water are disconnected)
Possible selections for AUX output
Indication
alarm
holiday
away mode
Control
circulation pump for hot water circulation
external heating medium pump
external damper for frost protection.
NOTE
The relevant distribution box must be marked with
a warning about external voltage.
Connecting external circulation pump
An external circulation pump is connected to the AUX out-
put, as illustrated below.
S735 External
1
2
3
NO
C
NC
AA2-X27
L N PE
L
N
PE