Menu 4 - My system
OVERVIEW
4.1 - Operating mode
4.2.2 - Solar electricity
1
4.2 - Plus functions
4.2.3 - SG Ready
4.2.5 - Smart Price Adaption™
4.4 - Weather control
4.5 - Away mode
4.7.1 - Variable electricity price4.7 - Energy price
4.7.2 - Fixed electricity price
4.8 - Time and date
4.9 - Language
4.10 - Country
4.11.1 - Installer details4.11 - Tools
4.11.2 - Sound when pressing button
4.11.4 - Home screen
4.30.4 - Fact. settings user4.30 - Advanced
1
Consult the accessory’s Installer Manual.
MENU 4.1 - OPERATING MODE
Operating mode
Alternative: Auto, Manual, Add. heat only
Manual
Options: Compressor, Additional heat, Heating
Add. heat only
Alternative: Heating
The operating mode for S735 is normally set to "Auto". It is
also possible to select operating mode "Add. heat only". Se-
lect "Manual" to choose which functions are to be activated.
If "Manual" or "Add. heat only" is selected, selectable options
are shown further down. Tick the functions you want to ac-
tivate.
Operating mode "Auto"
In this operating mode, S735 automatically selects which
functions are permitted.
Operating mode "Manual"
In this operating mode you can select what functions are
permitted.
"Compressor" is the unit that produces heating and hot
water for the home. You cannot deselect "compressor" in
manual mode.
"Additional heat" is the unit that helps the compressor to
heat the home and/or the hot water when it cannot manage
the entire requirement alone.
"Heating" means you obtain heating in the home. You can
deselect the function when you do not wish to have the
heating on.
Caution
If you deselect "addition" it may mean that insuffi-
cient hot water and/or heating in the accommod-
ation is achieved.
Operating mode "Add. heat only"
In this operating mode the compressor is not active, only
additional heat is used.
Caution
If you choose mode "Add. heat only" the com-
pressor is deselected and there is a higher operat-
ing cost.
MENU 4.2 - PLUS FUNCTIONS
Settings for any additional functions installed in S735 can
be made in the sub menus.
MENU 4.2.3 - SG READY
Here, you set the part of your climate system (e.g. room
temperature) that will be affected on activation of "SG
Ready". The function can only be used in mains networks
that support the "SG Ready" standard.
Affect room temperature
With low price mode on "SG Ready", the parallel offset for
the indoor temperature is increased by "+1". If a room sensor
is installed and activated, the desired room temperature is
increased instead by 1 °C.
With overcapacity mode on "SG Ready", the parallel offset
for the indoor temperature is increased by "+2". If a room
sensor is installed and activated, the desired room temper-
ature is increased by 2 °C instead.
NIBE S735Chapter 9 | Control - Menus46