Loading...
Transport
S735 should be transported and stored vertically in a dry
place.
Ensure that the heat pump cannot fall over during transport.
R
0
R
0
Check that S735 has not been damaged during transport.
However, the S735 can be carefully laid on its back when
being moved into the building. The centre of gravity is in the
upper part.
Assembly
Place S735 on a solid foundation indoors that can take the
heat pump’s weight.
Use the product’s adjustable feet to attain a horizontal
and stable set-up.
30 - 50 mm
30 - 50 mm
15 - 40 mm
20-55 mm
Because water comes from S735, the floor coating is im-
portant. A waterproof floor or floor membrane is recom-
mended.
Because water comes from S735, it is good if the area
where the heating pump is located is provided with floor
drainage.
Install with its back to an outside wall, ideally in a room
where noise does not matter, in order to eliminate noise
problems. If this is not possible, avoid placing it against a
wall behind a bedroom or other room where noise may be
a problem.
Wherever the unit is located, walls to sound sensitive
rooms should be fitted with sound insulation.
Route pipes so they are not fixed to an internal wall that
backs on to a bedroom or living room.
The heat pump's installation area should always have a
temperature of at least 10 °C and max 30 °C.
INSTALLATION AREA
Leave a free space of 800 mm in front of the product. Leave
free space between S735 and wall/other machinery/fit-
tings/cables/pipes etc. It is recommended that a space of
at least 10 mm is left to reduce the risk of noise and of any
vibrations being propagated.
800
NOTE
Ensure that there is sufficient space (300 mm)
above S735 for connecting ventilation ducts.