TECHNICAL DOCUMENTATION
S735Model
Air-water
Exhaust-water
Brine-water
Water-water
Type of heat pump
Yes No
Low-temperature heat pump
Yes No
Integrated immersion heater for additional heat
Yes No
Heat pump combination heater
Average Cold Warm
Climate
Medium (55°C) Low (35°C)
Temperature application
EN14825, EN16147, EN12102Applied standards
%144ƞ
s
Seasonal space heating energy efficiencykW5.6PratedRated heat output
Declared coefficient of performance for space heating at part load and at
outdoor temperature Tj
Declared capacity for space heating at part load and at outdoor temperature
Tj
-2.52COPdTj = -7 °CkW4.9PdhTj = -7 °C
-3.77COPdTj = +2 °CkW3.0PdhTj = +2 °C
-4.53COPdTj = +7 °CkW2.0PdhTj = +7 °C
-5.2COPdTj = +12 °CkW1.5PdhTj = +12 °C
-2.33COPdTj = bivkW5.5PdhTj = biv
-2.33COPdTj = TOLkW5.5PdhTj = TOL
-COPdTj = -15 °C (if TOL < -20 °C)kWPdhTj = -15 °C (if TOL < -20 °C)
°C-10TOLMin. outdoor air temperature°C-10T
biv
Bivalent temperature
-COPcycCycling interval efficiencykWPcychCycling interval capacity
°C65WTOLMax supply temperature-0.87CdhDegradation coefficient
Additional heatPower consumption in modes other than active mode
kW0.0PsupRated heat outputkW0.008P
OFF
Off mode
kW0.038P
TO
Thermostat-off mode
ElectricType of energy inputkW0.034P
SB
Standby mode
kW0.008P
CK
Crankcase heater mode
Other items
m
3
/h239Rated airflow (air-water)VariableCapacity control
m
3
/h0.68Nominal heating medium flowdB44 / -L
WA
Sound power level, indoors/outdoors
m
3
/hBrine flow brine-water or water-water heat
pumps
kWh3,156Q
HE
Annual energy consumption
For heat pump combination heater
%117ƞ
wh
Water heating energy efficiencyXLDeclared load profile for water heating
kWhQ
fuel
Daily fuel consumptionkWh6.90Q
elec
Daily energy consumption
GJAFCAnnual fuel consumptionkWh1,432AECAnnual energy consumption
NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – SwedenContact information
71Chapter 13 | Technical dataNIBE S735